Detect individual urinal occupancy status
  •  

     

    1. Description

    The crouching position sensor (laser, side) is used as an on-site collection slave station. According to the standard MODBUS-RTU communication protocol RS485 digital signal output upload, compatible with a variety of host computer configuration software.
    Can be widely used in IoT environment monitoring fields such as smart shopping malls, public toilets, stations and terminals...

     

     

    2. Index indicator

    DC power supply                                          

    DC12V

    Working environment -10~50 degrees, 5~95%RH
    Squatting parameter Probe (sender and receiver integrated); active sensing
    Measuring principle Laser inspection
    Measuring range 0~200cm
    RS485 output Modbus-RTU protocol

     

    3. Installation and debugging
    Dimensions: 89*89cm


    Wiring instructions

     

    Cable definition:
    ①Red line: DC 12V power supply+
    ②Black wire: power ground (GNG)
    ③Yellow line: RS485-A
    ④Blue line: RS485-B

     

     

     

    Concealed Installation Type