HOME    Smart Sensor    Animal Husbandry    Multi in one Animal husbandry monitoring sensor (NH3+H2S+CO2+air temperature +humidity)

Multi in one Animal husbandry monitoring sensor (NH3+H2S+CO2+air temperature +humidity)

NH3+H2S+CO2+air temperature +humidity
  •  

    1. Description

    Multi in one sensor (Air temperature and humidity, NH3, H2S, CO2)  As an on-site collection slave station, it outputs digital signals according to the standard MODBUS-RTU communication protocol RS485, suitable for long-distance network transmission.
    It can be widely used in factories, commercial buildings, intelligent aquaculture, public toilet environmental protection, animal husbandry, and other atmospheric environment monitoring.

     

    2. Parameter

    Air temperature measurement range: -40~80 degrees Celsius
    Air temperature measurement accuracy: ± 0.5 degrees
    Air temperature resolution: 0.1 degrees
    Air temperature repeatability: ± 0.2 degrees
    Air temperature drift: < ± 0.1 degrees Celsius/year

    Air humidity measurement range: 0-100RH%
    Air humidity measurement accuracy: ± 3RH%
    Air humidity resolution: 0.1% RH
    Air humidity repeatability: ± 1% RH
    Air humidity drift: < ± 0.5% RH/year
    Measurement stability time: 2 seconds
    Response time:<5 seconds

     

    NH3 measurement principle: electrochemical
    NH3 detection method: online monitoring, diffusion type
    NH3 measurement range: 0~50/100ppm
    NH3 resolution: 0.1PPM
    NH3 measurement accuracy: <± 4%
    NH3 measurement stability: <± 2%
    NH3 measurement repeatability: <± 2%
    NH3 measurement sensitivity: 0.1 ± 0.03uA (ppm)
    NH3 probe lifespan: 2 years (2ppm/NH3)
    Measurement stability time: 2 seconds
    Response time: < 60 seconds
    Temperature compensation: equipped with
    Internal filtration: removes cross interference of H2S, SOX, and NOX gases

     

    H2S measurement principle: electrochemical
    H2S detection method: online monitoring, diffusion type
    H2S measurement range: 0~50/100PPM
    H2S resolution: 0.1PPM
    H2S measurement accuracy: <± 4%
    H2S measurement stability: <± 2%
    H2S measurement repeatability: <± 1%
    H2S measurement sensitivity: 0.8 ± 0.15uA (ppm)
    H2S probe lifespan: 2 years (in air)
    Measurement stability time: 2 seconds
    Response time: < 30 seconds
    Temperature compensation: equipped with

     

    CO2 measurement method: NDIR dual channel non dispersive infrared measurement principle
    CO2 measurement range: 400~5000PPM
    CO2 measurement accuracy: ± 5%
    CO2 resolution: 1ppm
    CO2 measurement repeatability: ± 1%
    Preheating time: 120 seconds
    Response time: 60 seconds

     

    Communication interface: RS485
    Communication rates: 2400, 4800, 9600, 19200, 38400, 115200. Default 9600bps
    Communication protocol: MODBUS-RTU
    Data format: 1, 8, 1, 9600, N (1-bit start bit, 8-bit data bit, 1-bit stop bit, no checksum, 9600bps baud rate)
    Terminal category: Slave station
    Node address: 001~255
    Number of nodes: 31
    Transmission distance: 500 meters (RS485 communication dedicated cable)