1. Description
Multi in one sensor (Air temperature and humidity, NH3, H2S, CO2) As an on-site collection slave station, it outputs digital signals according to the standard MODBUS-RTU communication protocol RS485, suitable for long-distance network transmission.
It can be widely used in factories, commercial buildings, intelligent aquaculture, public toilet environmental protection, animal husbandry, and other atmospheric environment monitoring.2. Parameter
Air temperature measurement range: -40~80 degrees Celsius
Air temperature measurement accuracy: ± 0.5 degrees
Air temperature resolution: 0.1 degrees
Air temperature repeatability: ± 0.2 degrees
Air temperature drift: < ± 0.1 degrees Celsius/yearAir humidity measurement range: 0-100RH%
Air humidity measurement accuracy: ± 3RH%
Air humidity resolution: 0.1% RH
Air humidity repeatability: ± 1% RH
Air humidity drift: < ± 0.5% RH/year
Measurement stability time: 2 seconds
Response time:<5 secondsNH3 measurement principle: electrochemical
NH3 detection method: online monitoring, diffusion type
NH3 measurement range: 0~50/100ppm
NH3 resolution: 0.1PPM
NH3 measurement accuracy: <± 4%
NH3 measurement stability: <± 2%
NH3 measurement repeatability: <± 2%
NH3 measurement sensitivity: 0.1 ± 0.03uA (ppm)
NH3 probe lifespan: 2 years (2ppm/NH3)
Measurement stability time: 2 seconds
Response time: < 60 seconds
Temperature compensation: equipped with
Internal filtration: removes cross interference of H2S, SOX, and NOX gasesH2S measurement principle: electrochemical
H2S detection method: online monitoring, diffusion type
H2S measurement range: 0~50/100PPM
H2S resolution: 0.1PPM
H2S measurement accuracy: <± 4%
H2S measurement stability: <± 2%
H2S measurement repeatability: <± 1%
H2S measurement sensitivity: 0.8 ± 0.15uA (ppm)
H2S probe lifespan: 2 years (in air)
Measurement stability time: 2 seconds
Response time: < 30 seconds
Temperature compensation: equipped withCO2 measurement method: NDIR dual channel non dispersive infrared measurement principle
CO2 measurement range: 400~5000PPM
CO2 measurement accuracy: ± 5%
CO2 resolution: 1ppm
CO2 measurement repeatability: ± 1%
Preheating time: 120 seconds
Response time: 60 secondsCommunication interface: RS485
Communication rates: 2400, 4800, 9600, 19200, 38400, 115200. Default 9600bps
Communication protocol: MODBUS-RTU
Data format: 1, 8, 1, 9600, N (1-bit start bit, 8-bit data bit, 1-bit stop bit, no checksum, 9600bps baud rate)
Terminal category: Slave station
Node address: 001~255
Number of nodes: 31
Transmission distance: 500 meters (RS485 communication dedicated cable)